Gas Monitoring Equipment
| Product Description |
Picture |
|
The
FUMISCOPE Version 5.0 is designed exclusively for
fumigation work. In operation, it electrically pumps samples of air
from the space being fumigated, into a sensing element. The
concentration of fumigant gas in the air is shown on the digital
display in ounces per 1000 cubic feet/GM3. Anyone who can read a
digital watch can quickly make measurements with the
FUMISCOPE. Two controls
do all the adjusting. Air samples are collected through small tubes
placed at critical spots prior to introducing the gas. You can place
the tubes on one or more floors of a multistory structure over piles
of grain on the inside of packages, etc. Tubes are extended to a
convenient spot outside the fumigated area, gas is introduced, and
readings taken periodically with the
FUMISCOPE. You get continuous records of gas
concentration at each tube inlet.
For a copy of the Fumiscope 5.0
Operating Instructions, click
here.
|
 |
|
The RDA (Remote Data
Acquisition) Fumiscope provides essentially the same
function as the standard Fumiscope that Key Chemical has been
building for years. That is, an instrument that measures the gas
density of various fumigants in Ounces/1000 Cubic Feet/GM3.The
difference is that the RDA model can be left at the structure that
is being fumigated and remotely accessed via the standard telephone
system or cell phone from a remote computer (called the host
computer). In addition the RDA model can sample and test four
independent test points as opposed to the standard model's single
test point. Furthermore, up to 99 RDA models can be connected
together at one location and operate together to provide as many as
396 test points. The main advantage of the RDA model is the ability
to test from a remote location and to negate the necessity of an
employee having to be present at the job site. If the structure has
telephone and electric services then the instrument can use them. If
the structure does not have electricity and phone service, the
instrument can use a standard 400/600 volt/amp UPS and a
modem-capable cell phone. The unit can also be direct connected
using an RS232 cable. In addition, the program on the host computer
stores the results of testing for review and reporting. For an
additional fee, the program can be extended to automatically run
tests on a specified schedule without human intervention. |
 |
|
Interscan GF 1900
Founded in 1975,
Interscan
has established an international reputation in the field of toxic
gas detection. Long known as the go-to company for the tough
applications, we were contracted in the mid-1980's to develop a
practical sulfuryl fluoride monitoring instrument to be used for
clearance, after structural fumigation.
In just a short time, the new instrument became
the pest control industry standard, referred to as "The
Interscan."
The acceptance and popularity of this product line
could only have occurred based on a collaborative effort. We
gratefully acknowledge the suggestions and support from the
pesticide manufacturer, the distributors, and most of all, the pest
control operators.
For Information on the
Interscan, click
here.
For information on the Interscan Battery Pack, click
here.
For information on the Interscan Battery Charger, click
here.
For information on the Interscan Power Supply, click
here. |


 |
| TIF Detector (For
leak detection of Sulfuryl Fluoride)
Full featured but
easy to use, the original TIF detector. The TIF5750A offers
the detachable, flexible probe with micro-pump, leak intensity
indicators, and all the features you have come to know and trust.
Includes the patented SCAN mode that revolutionized leak detection.
Features
- LED Leak
Size Indicators
- Two
Sensitivity positions, including our unique ScanMode
- Reset
Button for instant re-calibration
-
Detachable probe
- High
efficiency pump
- Detects
ALL Halogenated Refrigerants
- Constant
Power Indication
- Carrying
case and spare sensing tip included
- U.S.
Patent #’s Re: 32,552; 4,282,521; 5,400,015
- Warranty:
One year warranty
- Battery
Life: 30 Hours (Alkaline)
- Size:
7.75X3.20X12.00 inch
- Weight:
"2.75 lb"
- Safety:
Certified to SAE J1627,UL Classified for Intrinsic Safety
|

For a video clip, click
here. |
Dräger Pac 7000
Small and robust, ergonomic and intuitive, economic and powerful
– the Dräger Pac 7000 is tailor-made for personal monitoring at
the workplace. This innovative single gas detector is equipped
with a wide range of functions and is suitable for many
different applications in day-to-day industrial settings. The
detector is an impressive instrument, offering a high level of
reliability and rapid warning against harmful concentrations of
many different gases.
For a brochure, click
here.
|

|
|
The Series C16
PortaSens II
portable gas leak
detector is a versatile tool for performing regular leak checks in
gas storage areas, around process equipment and piping, or in
confined spaces prior to entry. Designed for easy one-hand
operation, the detector contains an internal
sample pump and a flexible sampling wand to allow pinpoint location
of the source of leakage. A large character display insures that
measured values are easily visible, and a back-light for the display
insures readability in low or no light conditions.
A unique feature of the C16 detector
is its ability to measure a variety of different gases by simply
inserting the appropriate sensor for that gas. This means that one
detector can be used to measure over 30 different gases or vapors,
reducing the need to purchase individual detectors for each type of
gas. And sensors can be changed quickly and easily, without the need
for calibration when a sensor change is made.
For a brochure, click
here.
For an Operation Manual, click
here.
|
 |
Dräger Accuro Pump
and Colorimetric Tubes
Draeger-Tubes®
are
glass vials filled with a chemical
reagent that reacts to a specific chemical or family of chemicals. A
calibrated 100 ml sample of air is drawn through the tube with the
Draeger accuro®
bellows pump. If the targeted
chemical(s) is present the reagent in the tube changes color and the
length of the color change typicallyindicates the measured
concentration. The Draeger-Tube®
System is the world’s most popular form
of gas detection.
For a brochure on the pump and tubes, click
here.
|
  |
|
|
|